摘  要:[目的]建立一种石墨炉原子吸收光谱法测定尿中锰的方法。[方法]尿样用硝酸溶液稀释后,直接用石墨炉原子吸收法测定。[结果]石墨炉原子吸收法测定尿中锰,灰化温度可达1200℃,原子化温度为2400℃。标准曲线的线性范围为0.00~20.00μg/L,方法的检出限为0.2μg/L。测定样品的相对标准偏差在2.1%~4.6%之间,回收率在90.9%~106.8%之间。分别用标准加入法和标准曲线法测定不同尿样中的锰,经统计学处理,两者测定结果无显著性差异。[结论]该方法操作简便、迅速,具有良好的精密度和准确度,可用于尿中锰的测定。[Objective] To establish a method for determination of manganese in urine by graphite furnace atomic absorption spectrometry (GFAAS). [Methods] Manganese in urine was directly determined by GFAAS after the samples were diluted with nitric acid solution. [Results] In this method, the ashing temperature could reach 1200%. the atomization temperature was 2400℃. The linear range was from 0.00 to 20.00μg/L, the detection limit of the method was 0.2 μg/L. RSD of samples ranged from 2.1% to 4.6%. The average recoveries of samples were between 90.9%-106.8%. There were no significant differences between the results determined by standard curve method and standard addition method. [ Conclusion ] This method is simple, rapid, accurate and precise. It can be applied in the determination of manganese in urine.