锌—盐酸—硅烷化导气系统新银盐法测定药品中砷含量  被引量:1

Limit Test for Arsenic in Drugs with Modified Silanized Delivery System

在线阅读下载全文

作  者:李耀根[1] 肖志芳[1] 唐宏兵 刘红河 孙国防 

机构地区:[1]华西医科大学药学院

出  处:《药物分析杂志》1997年第1期30-32,共3页Chinese Journal of Pharmaceutical Analysis

摘  要:报道了将药典规定检砷第二法中的导气管硅烷化,把吸收液换为新银盐法的吸收液,从而建立测砷新方法。该法具有准确、灵敏度较高、试剂低毒、无需改变药典规定的装置和分析方法等特点。A new method for the determination of arsenic in drugs has been established.In this method,the delivery tubes of the apparatus for detecting arsenic adapted by Chinese pharmacopoeia(the second method)were silanized and 1% AgNO 3—0 4% polyvinyl alcohol-alcohol(1∶1∶2)mixture was used as the absorbent solution instead of Ag-DDC-CHCl 3 solution.This method is accurate and sensitive.It is not necessary to use poisonous reagents and to change original apparatus and major procedures as described in the pharmacopoeia.

关 键 词:导气管 硅烷化 新银盐法 药品分析 砷含量 

分 类 号:R927.12[医药卫生—药学]

 