内镜下高频电凝切除大肠息肉512例临床分析  被引量:13

Clinical Analysis of High Frequency Electrocoagulation and Electrocision under Colonoscope for Treating 512 Patients with Colorectal Polypus

在线阅读下载全文

作  者:吴和顺[1] 陈键林[1] 马佩炯 李文芳[1] 邹细岩 施广石[1] 

机构地区:[1]广东省汕头市第二人民医院消化内科,515011

出  处:《实用全科医学》2008年第5期477-478,共2页Applied Journal Of General Practice

摘  要:目的探讨内镜下高频电凝切除大肠息肉的临床效果及安全性。方法应用电子结肠镜与高频电凝发生器,在内镜直视下摘除息肉。结果512例经肠镜明确诊断、直径<2.0cm的大肠息肉采用高频电凝切除治疗,全部病例仅有5例并发迟发性出血,经内镜下电凝止血而痊愈,1例并发迟发性穿孔而行外科手术治疗。全部病例切除率100%,并发症发生率1.17%,随访6个月~1年大肠息肉未见复发。结论内镜下高频电凝切除治疗大肠息肉是一种简便、安全和有效的方法。Objective To investigate the clinical effect and safety of treatment with colorectal polypus by using high frequency electrocoagulation or electrocision under the colonoscope. Methods 512 patients with colorectal polypus were treated by high frequency electric electrocoagulation and electrocision under colonoscope. Results Delayed hemorrhage appeared in 5 cases and was cured by electrocoagulation, one case with delayed perforation was performed an operation. The total rate of excision was 100% and the complication rate was 1.17%. There was no recurrence in all the cases through 6 months to one year' s following up. Conclusions Removal of colorectal polypus by high frequency electric, coagulation under colonoscope is a safe and effective method for eolorectal polypus.

关 键 词:大肠息肉 结肠镜 高频电凝切术 分析 

分 类 号:R657.1[医药卫生—外科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象