Fusion Neutron Flux Monitor for ITER  被引量:1

Fusion Neutron Flux Monitor for ITER

在线阅读下载全文

作  者:杨进蔚 杨青巍 肖功珊 张炜 宋先瑛 李旭 

机构地区:[1]Southwestern Institute of Physics, Chengdu 610041, China [2]Beijing Nuclear Instruments Factory, Beijing 100020, China

出  处:《Plasma Science and Technology》2008年第2期141-147,共7页等离子体科学和技术(英文版)

基  金:National Natural Science Foundation of China(Nos.10175021,10675124)

摘  要:Neutron flux monitor (NFM) as an important diagnostic sub-system in ITER (international thermonuclear experimental reactor) provides a global neutron source intensity, fusion power and neutron flux in real time. Three types of neutron flux monitor assemblies with different sensitivities and shielding materials have been designed. Through MCNP (Mante-Carlo neutral particle transport code) calculations, this extended system of NFM can detect the neutron flux in a range of 10^4 n/(cm^2.s) to 10^14 n/(cm^2.s). It is capable of providing accurate neutron yield measurements for all operational modes encountered in the ITER experiments including the in-situ calibration. Combining both the counting mode and Campbelling (MSV; Mean Square Voltage) mode in the signal processing units, the requirement of the dynamic range (107) for these NFMs and time resolution (1 ms) can be met. Based on a uncertainty analysis, the estimated absolute measurement accuracies of the total fusion neutron yield can reach the required 10% level in both the early stage of the DD-phase and the DD-phase, the absolute measurement accuracy full power DT operation mode. In the advanced would be better than 20%.Neutron flux monitor (NFM) as an important diagnostic sub-system in ITER (international thermonuclear experimental reactor) provides a global neutron source intensity, fusion power and neutron flux in real time. Three types of neutron flux monitor assemblies with different sensitivities and shielding materials have been designed. Through MCNP (Mante-Carlo neutral particle transport code) calculations, this extended system of NFM can detect the neutron flux in a range of 10^4 n/(cm^2.s) to 10^14 n/(cm^2.s). It is capable of providing accurate neutron yield measurements for all operational modes encountered in the ITER experiments including the in-situ calibration. Combining both the counting mode and Campbelling (MSV; Mean Square Voltage) mode in the signal processing units, the requirement of the dynamic range (107) for these NFMs and time resolution (1 ms) can be met. Based on a uncertainty analysis, the estimated absolute measurement accuracies of the total fusion neutron yield can reach the required 10% level in both the early stage of the DD-phase and the DD-phase, the absolute measurement accuracy full power DT operation mode. In the advanced would be better than 20%.

关 键 词:neutron flux monitor international thermonuclear experimental reactor(ITER) assembly of fission chamber 

分 类 号:TL613[核科学技术—核技术及应用]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象