摘  要:含有氯霉素、抗菌素增效剂和磺胺新诺明的合成制药废水对生物处理有较强的抑制作用。研究表明,通过对厌氧菌和好氧菌的驯化、筛选和复配采用吹脱-厌氧-好氧串联工艺可有效降低废水的有机污染指标。经吹脱和厌氧水解酸化处理后,COD去除率为70%,再经好氧生化系统处理,COD去除率可达60%。试验结果表明装置运行效果稳定,为高浓度化学合成制药废水的生物处理提供了设计依据。There is a strong restraining function to microorganism treatment of chemical synthesized pharmaceutical waste water including CM, TMP and SM2, The anaerobe and aerobe training, filtrating and re-mating were investigated; the results showed that blowing - anaerobic-aerobic biologic combined Process can decrease the organic pollution concentration, Blowing-anaerobic process can reduce 70% CODcr and aerobic process can reduce 60% COD, The running effect is stabilization and it is worthwhile to design chemical synthesized pharmaceutical waste water treatment engineering on industrial process