摘  要:以受到工业废水污染的吉林省浑江水源为研究对象,采用高效混凝沉淀净水技术在低温低浊期进行生产性中试试验。通过药剂筛选试验确定的最佳药剂配合条件为:聚合氯化铝铁30mg/L与聚丙烯酰胺0.2mg/L。设备生产性试验表明,在2.0~3.Om^3/h负荷范围内,保证处理出水满足工业用水水质标准。玻璃柱絮凝试验结果显示原水温度的上升对混凝效果是有利的。High-effect coagulating pilot-scale experiment on Hun River water source, contaminated by industrial sewage, was carried out in low temperature and low tuibidity period. The optimum dosage was determined as: Polyaluminum ferric chloride (PAFC) 30 mg/L and Polyacrylamide (PAM) 0.2 mg/L. Furthermore the pilot-scale experiment results show that in the loading range from 2 to 3 m^3/ h, the processed water can reach the standard for industry utilization. It is also shown that increasing the water temperature can enhance the effect of coagulation.