高效液相色谱间接光度检测法测定心脏停搏液中钠、钾、钙、镁的含量  被引量:1

Determination of sodium, kalium, magesium and calcium in liquor of cardioplegia by high performance liquor chromatography-indirect photothetric determination method

在线阅读下载全文

作  者:袁成[1] 王景祥[1] 梁竹[1] 焦素云[1] 李凡东[1] 

机构地区:[1]济南军区总医院,济南250031

出  处:《药学实践杂志》1997年第4期234-237,共4页Journal of Pharmaceutical Practice

摘  要:本文用高效液相色谱间接光度检测法测定了心脏停搏液中钠、钾、钙、镁的含量。以SoherisorbSCX为固定相,0.35mmol/L硫酸铈的[水-乙腈(85:15),并用磷酸调pH至3.2~3.4]溶液为流动相,亚铈离子作为流动相平衡离子直接应用光度检测器测定,并与其他测定方法比较。结果表明,分离度较好,104%>回收率>97%,线性关系良好。结果与滴定法相比无显著性差异。该法具有操作简便快速,灵敏准确,适于作为制剂中4种离子的常规检测方法。To determine the content of sodium,kalium, magnesium and calcium in liquor of cardioplegia by HPLC-IPD method.METHOD: The chromatographic system consisted of Soherisorb SCX column and mobile phase of the solution of 0.35 mmol/L cerium sulphate in water-acetonitrile(85: 15), that were regulated to pH 3.2~3. 4 with phosphoric acid. Ceritnn was a balance - ion in mobile phase, therefore the content of sodium, kalium, magnesium and calcium were determined directly by photometer. The detected wave length was UV254 um. RESULTS:The mean recovery of 4 ion were between in 97~104% and deteCtion limits of sodium,kalium,magnesium and calcium were 5, 8, 5 and 4 ng. There was noremarkable betWeen in this HPLC-IPD method and titrative method. CONCLUSION: The method is constant, sensitive, have a concentration and is good for determination of sodium, kalium, magnesium and calcium concentration.

关 键 词:心脏停搏液     高效液相色谱法 

分 类 号:R972[医药卫生—药品] R927.2[医药卫生—药学]

 