摘  要:目的:找出氙气CT(XeCT)脑血流检查不成功的原因,从中吸取教训,为今后开展XeCT检查积累经验,为更进一步全面掌握XeCT检查,提高XeCT检查准确合格率,给临床提供可靠的第一手资料。方法:在我们已经完成检查的200余份病例中,筛选了10份不成功的病例进行分析,其中男性5例,女性5例,年龄16-71岁,男女比例各占50%。结果:该10例都是因为各种原因造成检查不成功。结论:由于各种原因造成XeCT头颅CT扫描不成功,其中包括有:由于病人自身不能耐受Xe气以及其他器官功能问题,导致不能配合,另有由于xeCT头颅CT检查刚刚开展,技术人员经验不足,导致误操作,使检查失败。Objective:To find the reasons responsible for unsuccessful in Cerebral blood flow (CBF) of Xe-CT examination so as to supply the correct, valid and reliable data about Cerebral blood flow (CBF) of the patients for clinicians. Methods: We selected ten cases for analysis from 200 patients who gained the Xe-CT. Male/female ratio was 1:1. Results:Every patient had his own problems which could not be examined with Xe-CT. Conclusion: Some patients could not be tolerant toward the xenon-oxygen mixed gases and have some problems of the organ function, thus leading to the incompatibility. Moreover, the technologist plays an important role in operating the Xe-CT. Insufficient experience results in maloperation.

关 键 词:氙气 脑血流 体层摄影术 X线计算机 

分 类 号:R814.42[医药卫生—影像医学与核医学] R743[医药卫生—放射医学]

 