改性石英砂过滤除磷试验研究  被引量:4

Experimental study on performance of iron-oxide coated sand for phosphorus removal

在线阅读下载全文

作  者:王俊岭[1] 冯萃敏[2] 龙莹洁[2] 李圭白[1] 杨艳玲[3] 

机构地区:[1]哈尔滨工业大学市政环境工程学院,黑龙江哈尔滨150090 [2]北京建筑工程学院环境能源工程学院,北京100044 [3]北京工业大学建筑工程学院,北京100022

出  处:《工业水处理》2008年第5期60-62,65,共4页Industrial Water Treatment

基  金:国家自然科学基金项目(50378004);北京市学术创新团队项目(BJE10016200611);北京市优秀人才培养资助项目(20071D0501700240)

摘  要:试验研究了三类改性滤料及涂铁改性石英砂对饮用水过滤去除微量磷的效果。结果表明,所有改性滤料对总磷的去除率均达到了80%以上,改性石英砂对总磷的去除率最高。对改性石英砂的试验表明,当pH为4.5~6.5时,总磷的去除率较高。进水总磷浓度越高,改性石英砂达到吸附饱和时间越短。The removal efficiency of phosphorus in drinking water by modified filter media, especially iron oxide-coated sand has been studied. It is surveyed thoroughly in order to obtain the drinking water biological stability. The results show that TP (total phosphorus) removal rate is up to 80% by filtration that uses all kinds of modified filter media,and TP removal rate is the highest by iron oxide-coated sand. Removal efficiency of TP is higher when pH value is within 4.5 to 6.6. The higher influent water TP concentration is, the shorter the time of reaching adsorbing saturation occurs.

关 键 词:改性滤料 涂铁石英砂 过滤 吸附 除磷 

分 类 号:TU991.2[建筑科学—市政工程]

 