检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:石程名[1] 宫世吉[1] 徐灿君[2] 杨颖[1]
机构地区:[1]重庆大学动力工程学院,重庆400044 [2]北京博奇电力科技有限公司,北京100022
出 处:《制冷学报》2008年第3期43-46,共4页Journal of Refrigeration
摘 要:针对气体类低品位热源驱动的溴化锂溶液吸收式制冷而提出采用竖管内降膜的发生器,其特点是溴化锂溶液薄液膜在竖管内由上而下流动,气体热源在管外部加热。通过实验得到降膜发生传热系数、放气范围、冷剂蒸汽产量与流量、热流密度的变化特性。实验结果表明:层流降膜时(Re<500),传热系数随Re增大而减小,随热流密度增加而显著增大。回归分析得到层流降膜的传热系数关系式:h=14009.87qw 0.0764 Re-0.5391。A falling film style generator in the lithium bromide absorption refrigeration system was proposed, in which the solution film flows down in vertical tubes and is heated by a low-class exhausted gas. The changes of heat transfer coefficient, deflation ratio and the steam mass flow rate in different solution volume flow and heat flux were obtained by the experiment. The experiment results show that the heat transfer coefficient decreases with the increase of Re number in film laminar flow (Re〈500) and increases significantly with the increase of the heat flux. The heat transfer coefficient in film laminar flow was deduced by analysis and polynomial regression, i.e., h= 14009.87qw^0.0764Re^-0.539.
关 键 词:工程热物理 溴化锂溶液 竖管 降膜发生 实验研究
分 类 号:TB657.9[一般工业技术—制冷工程] TQ051.8[化学工程]