干熄焦余热锅炉膜式水冷壁的自然循环情况分析  被引量:2

The Analysis on the Natural Circulation of the Membrane Wall in the CDQ Waste-heat Boiler

在线阅读下载全文

作  者:黄海苏[1] 郁鸿凌[1] 杜艳艳[1] 李瑞阳[1] 

机构地区:[1]上海理工大学,上海200093

出  处:《工业锅炉》2008年第3期20-23,共4页Industrial Boilers

基  金:"863"计划(No.2006AA05Z219);上海市科委重点攻关计划(No.071605127)

摘  要:分析了作为辐射蒸发受热面的膜式水冷壁布置于干熄焦余热锅炉的竖直烟道内,在低热负荷下水循环安全问题。干熄焦余热锅炉中的膜式水冷壁与传统锅炉中的膜式水冷壁的受热情况、自然水循环情况均不相同,对膜式水冷壁的布置及影响其自然循环安全性的因素进行分析,并提出相应的改善措施,为干熄焦余热锅炉的研发提供设计依据。As the radiation heating surface , the membrane wall is installed in the down pass of the CDQ waste-heat boiler. Studies the water circulation safety of the membrane wall under low heat flux. The heating condition and the natural circulation of the membrane wall in the CDQ waste - heat boiler are different from that in the traditional boilers. The arrangement of the membrane wall and the influencing factor on the natural circulation safety as well as the corresponding improvement measures are analyzed. It aims at offering some design basement of the CDQ waste - heat boiler for further research and development.

关 键 词:干熄焦余热锅炉 膜式水冷壁 自然循环 