检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:邹海峰[1,2] 姜桂兰[1,2] 徐淑坤 方肇伦[1,2]
机构地区:[1]长春科技大学应用理学院 [2]中科院沈阳应用生态所
出 处:《长春地质学院学报》1997年第4期464-468,共5页
摘 要:建立了应用流动注射在线共沉淀分离富集火焰原子吸收法测定天然水样中痕量铬的价态分析方法。利用铬(Ⅲ)在碱性条件下与氢氧化镧形成共沉淀而与共存离子分离并得到富集,沉淀不需过滤,直接用稀盐酸从编织反应器(KR)中溶解并洗脱下来,用原子吸收测定。本体系的浓集倍率22,检出限(3σ)0.8μg/L,相对标准偏差(n=11)2.72%,用水标样考察,分析结果与推荐值相符。该方法成功地用于天然水中铬的快速测定。A flow injection on-line Coprecipitation-FAAS system for the determination of Cr(Ⅲ) and Cr(Ⅵ) was developed. The analyte was preconcentrated and separated from the coexitting elements by on-line Coprecipitation with Lanthanum hydroxide. The precipitate was collected on the wall of the knotted reactor without filter, then dissolved on-line by 0.5 mol/L HCl at a flow rate of 6 mL/min and introduced into the nebulizer burner system of FAAS. A Concentration efficiency of 22 and a detection Limit (3σ) of 0.8 μg/L were achieved. The relative standard deviation (n=11) was 2.72%. The analytical results obtained for natural water samples were in good agreement with the certified values. The method has been applied success fully to determinate the trace amount of Cr(Ⅲ) and Cr(Ⅵ) in natural water samples.
正在载入数据...