金明热电厂反渗透预处理的改进  

Improvement of reverse osmosis pretreatment in Jinming thermo-electric plant

在线阅读下载全文

作  者:王艺林[1] 刘向朝[1] 王雪[1] 金利 

机构地区:[1]天津化工研究设计院,天津300131 [2]宁阳金明热电有限公司

出  处:《化工科技市场》2008年第6期20-22,共3页Chemical Technology Market

摘  要:金明热电厂反渗透系统预处理在技术改造前,保安过滤器滤芯更换频繁,运行一段时间后,系统脱盐率明显降低,降至93%,膜污染严重。反渗透膜经过离线清洗,脱盐率升至95%,系统预处理改造后滤芯更换周期加长,系统长时间运行脱盐率基本保持在95%,减轻了对膜的污染,保证了系统长期稳定运行。Abstract: Before the improvement in the pretreatment of reverse osmosis system in Jinming thermo-electric plant, it needed to change precision filter element frequently, and after some time, the desalination ability of system obviously decreased to 93 % and osmosis membrane was polluted seriously. After off-line cleaning, desalination rate raised to 95 %. The replacing period of filter element is prolonged and the membrane pollution is lightened. Morever the system could function steadily for a long time.

关 键 词:反渗透 膜污染 预处理 

分 类 号:TQ028.8[化学工程]

 