采用罗戈夫斯基线圈诊断径向束流  被引量:2

Measurement of radial beam current by double Rogowski coils

在线阅读下载全文

作  者:韩持宗[1] 刘庆想[1] 臧杰锋[1] 林远超[1] 

机构地区:[1]西南交通大学理学院,成都610031

出  处:《强激光与粒子束》2008年第6期985-988,共4页High Power Laser and Particle Beams

摘  要:罗戈夫斯基线圈具有结构简单、高频特性好等特点而被广泛应用于脉冲电流测量。提出了用两个自积分式罗戈夫斯基线圈诊断径向束流的方法,在此基础上设计了两个用于径向束流诊断的自积分式罗戈夫斯基线圈,对其进行了标定。当标准电流的上升沿为30 ns时,罗氏线圈响应时间约为10 ns;整个系统的测量误差约为4.7%。从标定结果来看,该系统的频率响应特性和测量精度能够满足ns级束流诊断的要求,该方法可以用于径向结构高功率微波器件的束流强度测量。Rogowski coil is used quite widely in measuring pulse current for its simple structure and good response in high frequency. In this paper,principle of using two self-integral Rogowski coils for radial electronic beam current measurement is analysed, and the Rogowski coils are calibrated by standard current. The calibrated results show that the diagnostic system could get the signal with response time less than 10ns and error about 4.7% when the rising edge of the standard current is 30ns and the system can meet the requirements of nanosecond beam measurement. Therefore, it can be used for measuring the intensity of a radial electronic beam eradiated by high-power microwave devices.

关 键 词:罗戈夫斯基线圈 自积分 径向束流 标定 

分 类 号:TM933.1[电气工程—电力电子与电力传动]

 