一种DC/DC模块电源失效原因分析及解决方法  被引量:1

Failure Cause Analysis and Resolution of a DC/DC Power Module

在线阅读下载全文

作  者:王坚[1] 雷云[2] 陈超[1] 

机构地区:[1]总参陆航部驻成都地区军事代表室,成都610036 [2]中国西南电子技术研究所,成都610036

出  处:《电讯技术》2008年第7期66-68,共3页Telecommunication Engineering

摘  要:对于在可靠性"三综合"(即温度、湿度和振动)试验中出现的质量问题,由于器件的相互关联性以及多种应力的共同作用,其故障原因或失效机理分析相对复杂,有效的解决方法在短期内往往难以出台。通过一种DC/DC模块电源在整机"三综合"试验中的失效原因和机理分析,并采用试验手段,确定振动应力是器件失效的主要原因。最后通过选择了合理有效的加固措施,彻底解决了DC/DC模块电源的失效问题。For the quality problem in reliability "three integrations" (temperature/humidity/vibration) test, the analysis of the failure cause or failure mechanism is relatively complex due to the element' s relevance and common effect of multi - stress, and it is difficult to provide an effective solution. In this paper, according to analysis of the failure cause and mechanism of a DC/DC power - module in equipment "three integrations" test, it is determined through test that the major cause of element' s invalidation is panting stress. Finally, by using reasonable and effective consolidation measures in equipment, the failure problem of DC/DC power- module is completely solved.

关 键 词:机载设备 DC/DC模块电源 失效分析 加固 

分 类 号:TN86[电子电信—信息与通信工程]

 