电除尘改造对厂用电的综合影响分析  被引量:2

Analysis of Comprehensive Impact of Electrostatic Precipitator Retrofit on Service Power

在线阅读下载全文

作  者:薛润 吴小洪[2] 

机构地区:[1]三河发电有限责任公司,河北省三河市065201 [2]北京华能自动化公司,北京市100088

出  处:《电力设备》2008年第4期77-79,共3页Electrical Equipment

摘  要:对比2台机组大修前后引风机、电除尘器用电单耗变化情况,对电除尘控制系统改造的节能效果进行了综合分析,得出电除尘改造后虽然对引风机单耗有一定的负面影响,但电除尘器本身节电效果显著,除尘效果有了明显改善,从机组整体来看,所起的节能降耗作用也是很可观的。The specific electricity consumptions of induced draft fans and electrostatic precipitators of two generating units before and after overhaul are contrasted,the energy-saving effect of control system retrofit of electrostatic precipitator is comprehensively analyzed,although the retrofit of electrostatic precipitator has a certain negative impact on the specific electricity consumption of induced draft fan,but the electricity-saving effect of electrostatic precipitator itself is obvious,the dust removal effect is improved evidently.Viewing from the unit as a whole,the energy-saving and consumption reduction effect is considerable.

关 键 词:电除尘器 厂用电 控制 节能 

分 类 号:TK223.27[动力工程及工程热物理—动力机械及工程]

 