摘 要:目的:建立测定抗生素S632-A中9-甲基链霉戊二酰亚胺(S632-A2)含量的HPLC方法。方法:采用Agilent TC-C18柱(150 mm×4.6 mm,5μm),流动相为甲醇-水(45∶55);流速:0.6 mL.min-1,检测波长233 nm,柱温为室温。结果:S632-A2进样量在0.88~8.76μg范围内呈良好的线性关系(r=0.999 5),回收率为99.97%,RSD为0.33%(n=9)。结论:此方法准确,重复性好,可为评价抗生素S632-A提供可靠依据。Objective:To develop a HPLC method for the determination of 9-methylstreptimidone in S632- A. Methods:The samples were separated on an Agilent TC-C18 column (150 mm × 4.6 mm,5 μm). The mobile phase consisted of methanol-water (45: 55). The flow rate was 0.6 mL-min-1 The detection wavelength was 233 nm. Results : The linear range of 9-methylstreptimidone was 0.88 - 8.76 μg( r = 0. 999 5 ). The average recovery of assay was 99.97% with RSD of 0.33 % (n = 9). Conclusion : The method is accurate, reproducible and can be used to evaluate the quality of S632-A.