石墨炉原子吸收法直接测定生活饮用水及其水源水中铝  被引量:16

Determination of aluminium in drinking water and source water by graphite furnace atomic absorption spectrometry

在线阅读下载全文

作  者:张琪[1] 

机构地区:[1]广州市番禺区疾病预防控制中心,广州511400

出  处:《中国卫生检验杂志》2008年第7期1293-1295,共3页Chinese Journal of Health Laboratory Technology

摘  要:目的:建立用次灵敏线石墨炉原子吸收法直接测定饮用水中铝,对测定条件各项指标进行优化,增大直接测定饮用水中铝的检测范围。方法:通过比较选择,以重铬酸钾为基体改进剂,在适宜的干燥、灰化、原子化温度下,直接进样测定。结果:饮用水铝浓度为0~500μg/L,标准曲线回归方式采用新合理拟合方式,相关系数r=1.000。检出限为4.2μg/L,加标回收率为96%~104%,相对标准偏差为4.7%-8.4%。结论:方法简便,灵敏度较高,检测浓度范围广,适宜测定生活饮用水中铝。Objective:To establish a method to determine Al in drinking water and source water at 257.4 nm by graphite furnace atomic absorption spectrometry, Selected and optimizated the analytical conditions. Enlarge the analytical scope of the method. Methods: KzCr2O4 was used as mixed matrix modifier. It was directly determined in suitable dry, ash, atomic temperature. Results:The detection range of the method was 0 -500 μg/L. The standard curve return way was new reasonable (r =1. 000). The detection limit was 4. 2 μg/L, the relative standard deviation were 4. 7% -8.4%, and the recovery rate were 96% - 104%. Conclusion:The method was rapid, simply, accurate and highly sensitive. It's a suitable method for determination of Al in water.

关 键 词:次灵敏线 石墨炉原子吸收法  饮用水 

分 类 号:O657.31[理学—分析化学]

 