检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:JIA YanMin LUO HaoSu OR Siu Wing WANG YaoJin CHAN Helen L W
机构地区:[1]State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 201800, China [2]Department of Applied Physics, The Hong Kong Polytechnic University, Hong Kong, China
出 处:《Chinese Science Bulletin》2008年第14期2129-2134,共6页
基 金:Supported by the Hi-Tech Research and Development Program of China (Grant No. 2006AA03Z107);National Natural Science Foundation of China (Grant Nos. 50432030, 50777065, 50602047);Scientific Innovation Program of the Chinese Academy of Sciences (Grant No. KGCX2-YW-111-7);Shanghai Municipal Gov-ernment (Grant No. 06DZ05016);Innovation Funds from Shanghai Institute of Ceramics of Chinese Academy of Sciences (Grant No. SCX0608);Research Grants Council of the HKSAR Government (PolyU 5255/03E and PolyU 5122/05E)
摘 要:Measured results of magnetoelectric (ME) and converse magnetoelectric (CME) effects of TbxDy1-xFe2-y/ Pb(Mg1/3Nb2/3)(1-x)TixO3/TbxDy1-xFe2-y (TD/PMNT/TD) and PMNT/TD/PMNT laminated composites are pre- sented. ME effect was determined by measuring laminate voltage output under a Helmholtz-gener- ated AC field biased by a DC field (0―1 kOe) (1 Oe = 79.58 A/m). The CME effect was measured by re- cording the voltage induced in a solenoid encompassing the ME sample while exposed to a DC bias field and PMNT layer driven by a 10 V AC source. The ME and CME responses in the two laminated structure are linear. The highest values of ME coefficients in TD/PMNT/TD and PMNT/TD/PMNT com- posites are 384 mV/Oe and 158 mV/Oe, respectively, while the highest values of CME coefficients in the two composites are 118 mG/V and 162 mG/V (1 G=10-4 T), respectively.Measured results of magnetoelectric (ME) and converse magnetoelectric (CME) effects of TbxDy1-xFe2-y/ Pb(Mg1/3Nb2/3)(1-x)TixO3/TbxDy1-xFe2-y (TD/PMNT/TD) and PMNT/TD/PMNT laminated composites are presented. ME effect was determined by measuring laminate voltage output under a Helmholtz-generated AC field biased by a DC field (0-1 kOe) (1Oe = 79.58 A/m). The CME effect was measured by recording the voltage induced in a solenoid encompassing the ME sample while exposed to a DC bias field and PMNT layer driven by a 10 V AC source. The ME and CME responses in the two laminated structure are linear. The highest values of ME coefficients in TD/PMNT/TD and PMNT/TD/PMNT composites are 384 mV/Oe and 158 mV/Oe, respectively, while the highest values of CME coefficients in the two composites are 118 mG/V and 162 mG/V (1 G=10^-4 T), respectively.
分 类 号:TG13[一般工业技术—材料科学与工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.206