作 者:田浩[1]
机构地区:[1]太原市建筑设计研究院
出 处:《山西建筑》2008年第22期184-185,共2页Shanxi Architecture
摘 要:分析了我国北方地区面临的采暖问题,探讨了风冷热泵的低温性能,通过对三种风冷热泵机组低温性能的测试,指出采用地板采暖的优越性,同时指出风冷热泵结合地板采暖将是替代燃煤采暖的最经济的清洁采暖系统。The faced heating problems in northern area in China was analyzed, the low temperature performance of air-cooled heat pump was discussed. By testing the low temperature performance of three air-cooled heat pumps, the advantage of using floor heating was pointed, meanwhile, it was pointed out that air-cooled heat pump combining with floor heating would be the most economic clean heating system replacing coal-fired heating.
分 类 号:TU832[建筑科学—供热、供燃气、通风及空调工程]