检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:马力[1]
出 处:《电力电容器与无功补偿》2008年第3期11-14,54,共5页Power Capacitor & Reactive Power Compensation
摘 要:控制有源电力滤波器(APF)直流侧电压为适当值是保证其具有良好补偿性能的一个重要因素,以并联型有源电力滤波器交流和直流侧瞬时功率平衡为基础,对并联型有源电力滤波器直流电容平均电压与脉动电压的变化规律进行研究,分析了它们对并联型有源电力滤波器性能的影响。为了克服这种影响,提出了在补偿电流中注入基波有功电流和增大直流侧电容量控制直流电压稳定的一种方法。仿真结果验证了所提出方法的正确性和有效性。To control the DC side capacitor voltage at an adequate value is an important link which guarantees the excellent compensation characteristics of Active Power Filter (APF). The paper bases on the instantaneous power balance of shunt active power filter AC side and DC side, discusses the change rule of DC capacitor average and fluctuant voltage, analyses their influence on the performance of shunt APF. In order to overcome the influence, a control method is proposed by injecting active current in the compensation current and enlarging the capacity of DC capacitor to control the DC capacitor voltage steadily. Lastly, simulation results are presented to verify the validity of the proposed control algorithm.
关 键 词:并联型单相有源电力滤波器 直流侧电容电压控制 电能质量
分 类 号:TN713.8[电子电信—电路与系统]