摘  要:移动基站的耗电占了移动公司整个能耗的73%,而基站空调耗电占了基站能耗的51%。为响应国家节能减排工作安排,结合企业自身发展需求,在确保基站正常运行所需外部环境前提下,湘西自治州移动分公司基于负压式空气通风原理,开发了利用地下管道降温,同时辅助以部分控制设备的管道负压式智能节能通风系统。The electric power consumption of mobile basic station is the 73% of whole power consumption of mobile company, while the electric power consumption of air-conditioning is the 51 % of the whole basic station power consumption. In answer to the energy-saving and eiection-decreasing work of the country, and combined with the self need of development under the premise of insure all the outside environment needed to make the basic station work normally, the Xiangxi Autonomy Zone branch company develops the pipeline vacuum intelligent energy-saving and ventilation system based on the principle of vacuum ventilation which using the underground pipeline to lower the temperature.