检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]湖北省机电研究设计院 [2]湖北省建材研究设计院,湖北武汉430071
出 处:《冶金分析》2008年第7期76-78,共3页Metallurgical Analysis
摘 要:基于0.6mol/L硝酸介质中,显色剂二溴对甲基偶氮磺与铬(Ⅵ)的褪色反应,建立了测定铬青铜中铬(Ⅶ含量的褪色光度分析方法。讨论了吸收光谱、酸度、试剂用量、时间、络合物组成、干扰离子等因素的影响,确定了反应的最佳条件。在25mL溶液中,铬(Ⅵ)量在0.8~12μg范围内符合比尔定律,表观摩尔吸光系数为4.34×10^4L·mol^-1·cm^-1.方法可用于直接测定铬青铜中铬(Ⅶ的含量,结果与二苯基碳酰二肼光度法(DPC)相符,其相对标准偏差(RSD)在0.97%~1.02%之间。A sensitive spectrophotometric method was developed to determine chromium(Ⅵ) in chromium bronze on the basis of discoloring reaction of chromium(VD-dibromo-p-methylsulfonazo system in 0.6 mol/L HNO3 medium. Some factors such as absorption spectra,acidity, dosage of reagent, time, composition, interference of coexisting ions on the reaction were discussed, and the optimal reaction conditions were established. Beer's law was obeyed in the range of 0. 8-12 μg/25 mL for chromium(Ⅵ) with an apparent molar absorptivity of 4.34× 10^4 L· mol^-1· cm^-1. The proposed method could be directly used in the determination of Cr(Ⅵ) in chromium bronze,and the results were in good agreement with those of diphenlycarbazide spectrophotometry (DPC). The relative standard deviation is 0.97%-1.02%.
分 类 号:TG115.3[金属学及工艺—物理冶金]