南水北调东线一期工程源头泵站优化运行研究  被引量:11

Study on source pump station optimal operation of first-stage Eastern Route of South-to-North Water Diversion Project

在线阅读下载全文

作  者:冯晓莉[1] 仇宝云[1] 黄海田[1] 朱月新 

机构地区:[1]扬州大学能源与动力工程学院 [2]江苏省苏北供水局,南京210029

出  处:《水力发电学报》2008年第4期48-53,共6页Journal of Hydroelectric Engineering

基  金:国家自然科学基金项目(50179032);全国优秀博士学位论文作者专项资金(2007)

摘  要:南水北调东线一期工程源头泵站主要由江都站、宝应站组成。在源头泵站两条输水线路出口交汇处流量和水位一定的前提下,以泵机组总功率最小为目标,建立了源头泵站运行优化数学模型,其中考虑了泵站输水河道水量损失和水力损失。运用退火遗传算法求解,确定每条输水线路水位和流量分配、各泵站泵装置扬程、开机台数和机组运行工况。将优化结果与常规运行方案比较,结果表明,实施优化运行后,泵机组总运行功率可减小15.65%,优化运行方案的节能效果明显。Source pump stations of the first-stage Eastern Route of South-to-North Water Diversion Project are mainly made up of Jiangdu pump stations and Baoying pump station. On the premise of certain discharge and water level at cross point of the two source pump station transmission lines, aiming at the least total power of pump units, the mathematical models of source pump station optimal operation are established which include the discharge loss and hydraulic loss of transmission lines. Water levels and discharge distributions of the transmission lines, pump assembly heads, the number of running pump units and operation of each pump station are determined by annealing genetic algorithm. The optimal results are compared with normal operation schemes. The results indicate that total power of pump units could decrease by 15.65% by optimal operation. The energy-saving effect of the optimal operation scheme is obvious.

关 键 词:水力机械 南水北调东线一期工程 源头泵站 优化运行 退火遗传算法 

分 类 号:TV675[水利工程—水利水电工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象