摘  要:针对传统医院建筑空调能耗较高的特点,提出使用温湿度独立控制空调系统,即利用品位相对较低的约18℃冷冻水去除室内余热,采用溶液除湿装置去除余湿,同时采用高效热回收装置充分利用室内排风冷量,可以达到节能30%以上又同时满足室内温湿度要求的目的。For the high energy consumption of traditional air-conditioning system for hospitals, independent temperature and humidity control air-conditioning system was put forward. The low-grade chilled water about 18℃ was used to remove indoor waste heat. Liquid desiccant equipment was used to remove indoor waste damp. High efficiency heat recovery equipments were utilized to make use of the quantity of cold in exhaust air sufficiently. It can save about 30% energy consumption and meet the demand of control temperature and humidity simultaneity.

关 键 词:医院空调系统 温湿度独立控制 溶液除湿 节能 