检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:曾山[1] 周欣[1] 涂悦[1] 姚旻[1] 李玉明[1]
机构地区:[1]中国人民武装警察部队医学院附属医院武警部队心血管病研究所,天津300162
出 处:《中华高血压杂志》2008年第8期737-741,共5页Chinese Journal of Hypertension
基 金:武警总部科研基金(WY2005-5)
摘 要:目的采用压力容积导管研究慢性压力超负荷对高血压大鼠左心室(LV)血流动力学的影响。方法10只6月龄雄性卒中易感性自发性高血压大鼠(SHR-SPs)和10只同月龄雄性 Wistar-Kyoto(WKY)大鼠分别作为高血压组和对照组。对两组大鼠行在体 LV 血流动力学检测,大鼠麻醉后经右颈总动脉向 LV 内插入2F Millar 压力容积导管(SPR-838),记录大鼠稳定状态和改变心脏前负荷时的压力-容积(P-V)变化。结果与 WKY 大鼠比较,SHR-SPs LV 收缩末压、LV 收缩末容积和室内压最大上升速率(+dP/dt_(max))均增高,而射血分数、每搏输出量和心排血量均出现降低(P<0.05)。在压力负荷的影响下,SHR-SPs LV 收缩末压力容积曲线的斜率代偿性增高(P<0.05)。SHR-SPs LV 舒张末压、LV 舒张末容积和 LV 压力衰退的时间常数均高于 WKY 大鼠(P<0.05),而室内压最大下降速率(-dP/dt_(min))低于 WKY 大鼠(P<0.05)。与 WKY 大鼠比较,SHR-SPs 在体 LV P-V 曲线出现了明显的右移。结论 SHR-SPs 发生了 LV 舒张功能障碍及收缩功能减低,并在此基础上伴有一定程度的 LV 扩张。压力容积导管能够客观准确地评价大鼠的心功能。Objective Using pressure-volume conductance catheter system to investigate the effect of chronic pressure-overload on left ventricular (LV) hemodynamics in hypertensive rats. Methods Six-month-old male stroke-prone spontaneously hypertensive rats (SHR-SPs, n= 10) and age-matched male Wistar-Kyoto (WKY) rats (n=10) were used. The animals were anaesthetized and a 2F Millar pressure-volume conductance catheter (SPR- 838) was inserted through right carotid artery into LV to measure pressure-volume (P-V) relationship. Results We found that left ventricular end-systolic pressure, left ventricular end-systolic volume and +dP/dtmax were all remarkablely higher in SHR-SPs than those in WKY rats (P〈0.05). Compared with WKY rats, ejection fraction, stroke volume and cardiac output were decreased in SHR-SPs ( P〈0.05). The slope of left ventricular end systolic pressure-volume relationship was greatly elevated in SHR-SPs. The constant of isovolumeric relaxation (Tau) was prolonged in SHR-SPs (P〈0.05) and left ventricular end-diastolic pressure and left ventricular end-diastolic volume were significantly increased in SHR-SPs than in WKY rats (P〈0.05). In addition, -dP/dtmin. was decreased in SHR-SPs (P〈0.05). The in vivo P-V loop curve was notably rightward shifted in SHR-SPs. Conclusion These results show that pressure-overload could induce LV diastolic dysfunction, deterioration of systolic performance and partial LV dilation. The pressure-volume conductance catheter system is an useful tool for objective and accurate assessment of cardiac function in rats.
分 类 号:R544.1[医药卫生—心血管疾病] R285.5[医药卫生—内科学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7