检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]天津商业大学
出 处:《制冷与空调》2008年第4期44-47,共4页Refrigeration and Air-Conditioning
摘 要:对R290/CO2自然工质复叠式制冷系统低温冷冻箱进行设计和试验,冷冻箱内的温度在2个小时内平稳下降54.5℃,并保持在-41℃,这说明冷冻箱的设计合理,温度的稳定性较好,为自然工质R290/CO2复叠式制冷系统的推广应用打下了一定的基础。By designing and experiment on freezing case of cascaded refrigeration system that uses natural refrigerants R290 and CO2 for low temperature, obtains the results that the temperature inside freezing case decreases 54.5 ℃ smoothly in 2 hours, and the temperature inside freezing case maintains - 41 ℃ for more than 2 hours. So it can be concluded that the design of freezing case is reasonable and the temperature inside freezing case is steady. All the above studies can provide basis for the popularization and application of natural refrigerants R290/CO2 cascaded refrigeration system.
分 类 号:TB657[一般工业技术—制冷工程]