莱钢1880m^3高炉设备技术改造降低休风率实践  

Practice of Reducing 1 880 m^3 BF Blow-down Percentage by Equipment Technology Reconstruction in Laiwu Steel

在线阅读下载全文

作  者:李贡生[1] 程序录[1] 杨吉广[1] 王秀花[1] 

机构地区:[1]莱芜钢铁集团有限公司,山东莱芜271104

出  处:《山东冶金》2008年第4期10-11,共2页Shandong Metallurgy

摘  要:由于设计施工质量的问题,莱钢1 880 m3高炉投产后设备故障频繁,经常引起慢风、休风,严重影响了高炉稳定顺行。通过技术攻关,加固送风设施,改善开口装置,对关键设备进行技术改造,保证了设备正常运行,设备休风率降为零,高炉利用系数达到2.68 t(/m3.d),炉前设备年降低成本80~100万元。Because much problems existed in designing and construction, Laiwu Steel 1 880 m^3 BF often appeared equipment trouble since startup, reducing-wind and blow-down regularly happened, which seriously affected normal production. Through technical reconstruction for example, reinforcing air supply equipment and improving tapping machine, transforming the key equipment. Then that assuring the equipment normal work, equipment blow-down percentage reached zero, productivity achieved 2.68 t/(m^3· d), economic effectiveness only furnace front reduced 8 - 10 hundred thousand Yuan every year.

关 键 词:高炉 设备故障 技术改造 休风率 利用系数 

分 类 号:TF544.7[冶金工程—钢铁冶金]

 