氧压机DCS控制系统启动程序改造  被引量:1

Modification of starting program for DCS control system of oxygen compressor

在线阅读下载全文

作  者:张永康[1] 侯志勇[1] 袁记将[1] 王建新[1] 

机构地区:[1]安阳钢铁股份有限公司制氧厂,河南省安阳市安钢大道455004

出  处:《深冷技术》2008年第5期60-64,共5页

摘  要:14000m3/h空分设备氧压机在试车过程中,因启动程序存在缺陷,启动过程中不能联锁停车。在修改启动程序的过程中发现了控制系统存在的一些新问题,对氧压机的DCS控制系统进行了相应修改,完善控制功能。着重介绍对氧压机在启动过程中因进气压力低而联锁停车功能的修改,达到安全运行的目的。Oxygen compressor of 14000m3/h air separation unit was not able to realize interlock shutdown during the startup process due to the fault of starting program. Some problems in control system were also newly found when modifying the starting program. Corresponding modifications have been conducted on the DCS control system to improve the control function. Emphasis was focused on the modification of the interlock shutdown function induced by low inlet pressure during startup process of oxygen comoressor so as to realize safe operation.

关 键 词:氧压机 DCS 启动程序 

分 类 号:TH452[机械工程—机械制造及自动化]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象