成都地铁浅埋区间隧道自然通风排烟方式的热烟试验研究  被引量:11

The hot smoke test on nature smoke exhaust in Chendu Metro's shallow-burying intersectional tunnel

在线阅读下载全文

作  者:谢元一[1] 张晓明[1] 胡忠日[1] 杨庆[2] 潘京[2] 祁晓霞[2] 刘沙[2] 

机构地区:[1]公安部四川消防研究所,四川都江堰611830 [2]四川省消防总队,四川成都610072

出  处:《消防科学与技术》2008年第10期739-741,共3页Fire Science and Technology

摘  要:区间隧道采用自然通风的方式进行排烟在国内尚属首次。采用热烟试验方法在建成的实体隧道现场,验证了成都地铁浅埋区间隧道现有的通风竖井间距和通风面积能够满足隧道排烟的要求。烟层高度高于人体特征高度,烟气通过区间隧道最近的两个通风竖井排出,烟气蔓延区域控制在两个通风竖井之间,来自隧道内外的自然风对排烟效果的影响不大。Nature smoke exhaust in metro's shallow-burying intersectional tunnel is the first time in China. In the paper, the author get a smoke test in Chengdu Metro's shallow burying interseetional tunnel, and validated that the existed ventilation shaft interval and area can he content with the demand of the tunnel smoke exhaust. The smoke layer level is higher than the human body height. The smoke flow exhausts from the nearest ventilation shaft, and the smoke filled zone is controlled between two ventilation shafts. The wind in and out the tunnel has small influence to exhaust effect.

关 键 词:地铁 浅埋区间隧道 自然排烟 热烟试验 

分 类 号:X924[环境科学与工程—安全科学] TU96[建筑科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象