2种溴隐亭片的质量分析  

Quality analysis of two kinds of bromocriptine tablets

在线阅读下载全文

作  者:邵路平[1] 郁颖佳[1] 陈益乐[1] 陈斌[1] 周涛[1] 朱逸清[1] 段更利[1] 

机构地区:[1]复旦大学药学院药物分析教研室,上海200032

出  处:《中国新药与临床杂志》2008年第9期671-674,共4页Chinese Journal of New Drugs and Clinical Remedies

摘  要:目的对市售2种溴隐亭片的质量进行评价。方法参照2种产品的自身质量标准及中国药典2005版对2种产品的质量进行系统考察。结果2种产品的主要测定结果为:脆碎度检查减失重量均小于1%;含量均匀度的A+1.80 S分别为(9.2±s 1.4)和(8±4);60 min时的溶出度均大于80%;含量测定结果分别为(107.9±2.1)%和(107.4±2.2)%。结论2种溴隐亭片的各项质量分析结果均符合中国药典规定。AIM To evaluate the quality of two kinds market available bromocriptine tablets. METHODS According to two reference standards and the Chinese Pharmacopoeia 2005 edition, systematically examining the two products' quality was undertaken. RESULTS The outcomings of the two products were as follows: friability test minute the weight loss were both less than 1%; content uniformity (A +1.80 S) were (9.2 ± s 1.4) vs (8 ± 4) ; dissolution of the cumulative dissolution percentages at 60 th minute were both above 80 % ; content determinations were (107.9 ± 2.1) % vs (107.4 ± 2.2) %. CONCLUSION The quality analysis results of the two kinds bromocriptine tablets are in accord with their respective requirements or the Chinese Pharmacopoeia.

关 键 词:溴隐亭 色谱法 高压液相 药物评价 质量分析 

分 类 号:R965[医药卫生—药理学]

 