检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:徐鸿志[1] 陈志伟[1] 刘东武[1] 牛金叶[1]
出 处:《理化检验(化学分册)》2008年第10期911-912,926,共3页Physical Testing and Chemical Analysis(Part B:Chemical Analysis)
基 金:山东省科技攻关项目(2007GG10003047);山东省科学仪器设备升级改造项目(2006GG1108097-06)
摘 要:采用改进的微波消解程序处理矿物渣样品,用185Re作为内标同位素,以在线内标加入法补偿样品的基体干扰,提出了测定矿物渣中微量铀和钍的电感耦合等离子体质谱法。铀和钍的方法检出限分别为0.017,0.021 ng.g-1;铀和钍的平均加标回收率(n=6)分别为99.0%,101.3%;相对标准偏差(n=6)分别为4.02%和3.54%。两种标准物质中铀和钍的测定结果与标准值相符合。A method of ICP-MS determination of micro-amounts of uranium and thorium in mineral slags, with the application of an improved program of microwave assisted sample digestion, using ^185 Re as istopic internal standard to compensate for matrix interference by on-line addition of internal standard, was proposed. Detection limits (3S) were found to be 0. 017 ng · g^-1 and 0. 021 ng · g^-1 for uranium and thorium respectively. Tests for recovery and precision were made by adding standard solutions of uranium and thorium to a slag sample and analyzed by the proposed method, giving values of average recovery 99. 0% and 101.3% for uranium and thorium, and values of RSD's (n= 6) 4. 02% and 3. 54% respectively. Two CRM's were analyzed by the proposed method, giving results in consistency with the certified values.
关 键 词:电感耦合等离子体质谱法 矿物渣 铀 钍