检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]Department of Instrument Science and Engineering, Shanghai Jiaotong University
出 处:《Journal of Shanghai Jiaotong university(Science)》2008年第5期600-604,共5页上海交通大学学报(英文版)
基 金:the National Natural Science Foundation of China (No. 30800235);the Youth Teacher Fund of Research Fund for the Doctoral Program of Higher Education of China (No. 20070248094);the Youth Teacher Funds of Shanghai Jiaotong University(No. 06DBX006)
摘 要:This artificial anal sphincter (AAS) is used to help patients who are in severe incontinence. It consists of two parts. The first part is taken outside with patients. The second is implanted in the bodies to provide independent evacuation for patients. It is powered through transcutaneous energy transmission by the first part. There are two sensors in the second part. One sensor measures the pressure in the cuff-clamp around the recta. The other measures the pressure of the recta. As soon as the pressure measured by the later reaches the threshold, a signal is sent out to patients through wireless communication to alarm patients preparing defecation. Patients can give a start signal to begin defecating after they are ready. And they can also give a signal to stop defecating like a healthy person. With the aids of the novel medical device, patients can defecate as a healthy person. The first generation of this AAS is presented.This artificial anal sphincter (AAS) is used to help patients who are in severe incontinence. It consists of two parts. The first part is taken outside with patients. The second is implanted in the bodies to provide independent evacuation for patients. It is powered through transcutaneous energy transmission by the first part. There are two sensors in the second part. One sensor measures the pressure in the cuff-clamp around the recta. The other measures the pressure of the recta. As soon as the pressure measured by the later reaches the threshold, a signal is sent out to patients through wireless communication to alarm patients preparing defecation. Patients can give a start signal to begin defecating after they are ready. And they can also give a signal to stop defecating like a healthy person. With the aids of the novel medical device, patients can defecate as a healthy person. The first generation of this AAS is presented.
关 键 词:artificial anal sphincter(AAS) transcutaneous energy transmission wireless communication pressure sensor FEEDBACK
分 类 号:R318.1[医药卫生—生物医学工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.28