大学生公寓多联机及半集中式空调系统能耗分析  被引量:6

Energy Consumption Analysis of Multi-split and Semi-central Air Conditioning Systems in Undergraduate Apartment

在线阅读下载全文

作  者:王海刚[1] 钱付平[1] 陈乐端[1] 聂新猛 

机构地区:[1]安徽工业大学建筑工程学院,安徽马鞍山243002 [2]南通建工集团股份有限公司,江苏南通226006

出  处:《节能技术》2008年第5期475-478,共4页Energy Conservation Technology

摘  要:选择安徽某大学生公寓作为研究对象,根据工程实际规模,分别配置半集中式空调系统和多联机式空调系统,分析影响空调系统运行能耗的各种因素,对两种系统的实际运行情况进行分析对比。结果表明:和半集中式空调系统比较,多联机式空调系统在相同条件下约节能30%。By selecting an undergraduate apartment in Anhui as the research object, based on the project size, semi - central air conditioning system and multi - split air conditioning system are eonfigared, and the factors which effect the energy consumption of the air conditioning are analyzed. By comparing the energy consumption of these two systems, the results show that the multi - split air conditioning system can save 30% of energy at the same conditions than the semi - central air conditioning system.

关 键 词:多联机系统 半集中式空调系统 大学生公寓 能耗分析 

分 类 号:TU831.3[建筑科学—供热、供燃气、通风及空调工程]

 