气相色谱法测定用于食品包装的PVC保鲜膜中作为增塑剂加入的二-(2-乙基己基)己二酸酯  被引量:4

GC Determination of Di-(2-Ethyl-Hexyl)Adipate as a Plastizizer in PVC Fresh-keeping Film for Food Package

在线阅读下载全文

作  者:袁丽凤[1] 叶海雷[1] 邬蓓蕾[1] 俞雄飞[1] 华正江[1] 

机构地区:[1]宁波出入境检验检疫局,宁波315012

出  处:《理化检验(化学分册)》2008年第11期1103-1104,共2页Physical Testing and Chemical Analysis(Part B:Chemical Analysis)

摘  要:聚氯乙烯(PVC)保鲜膜与作为增塑剂加入的二-(2-乙基己基)已二酸酯(DEHA)一起用环已酮溶解后于溶液中加入无水乙醇使PVC生成沉淀而与DEHA分离,将滤液用无水乙醇定容为100 mL供气相色谱测定。用HP-5毛细管柱(15 m×0.32 mm,0.25μm)作为色谱柱,按预定程序从140℃升温至270℃(气化温度),并记录输出色谱信号。用色谱峰的保留时间进行定性分析,用标准曲线进行定量分析。方法的检出限(3S/N)为0.9 mg·L^(-1),测得方法的回收率在96.8%~101.4%之间,测得结果的相对标准偏差(n=5)为1.1%。The plasticizer, di-(2-ethyl-hexyt) adipate (DEHA) together with the PVC fresh-keeping film was dissolved with cyclohexanone, and separated from PVC by precipitation of the latter by adding absolute ethanol. The filtrate was diluted to 100 mL with absolute ethanol and used for GC determination. The HP-5-capillary chromatographic column (15 m×0. 32 mm, 0. 25μm) was used and worked according to the prescribed program of temperature elevation from 140 ℃ to 270 ℃, and the output signal was recorded. Retention time of the chromatographic peak was used in qualitative analysis and standard curve was used in quantitative analysis. Detection limit (3S/N) of the method found was 0. 9 mg· L^-1. Values of recovery obtained were in the range of 96. 8% to 101.4%, and value of relative standard deviation (n=5) obtained were 1.1%.

关 键 词:气相色谱法 增塑剂 二-(2-乙基己基)己二酸酯 聚氯乙烯 食品保鲜膜 

分 类 号:O657.31[理学—分析化学]

 