检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:程海东[1] 许淳淳[1] 吕国诚[1] 曲秀华[1]
机构地区:[1]北京化工大学材料科学与工程学院,北京100029
出 处:《腐蚀与防护》2008年第11期674-677,共4页Corrosion & Protection
基 金:中石化项目"三级炼油外排污水回用循环水成套技术开发"(306021)
摘 要:采用慢应变速率法和恒应变原位电化学测试法研究了304不锈钢在60℃的模拟循环冷却水中,氯离子对其耐蚀性能的影响。结果表明:Cl^-浓度小于600 mg/L时,随着Cl^-浓度的增加,膜破裂电位迅速负移,点蚀敏感性增大,未发生应力腐蚀破裂;Cl^-浓度大于600 mg/L时,随着Cl^-浓度的增加,膜破裂电位较负且变化缓慢,应力腐蚀破裂敏感性增大。The effect of Cl^- on the corrosion resistance of 304 stainless steel in simulated circular cooling water at 60℃ was studied by means of in-situ electrochemical tests under constant strain condition and slow strain rate tests (SSRT). When Cl^- concentration was below 600 mg/L, the pitting potentials evolved towards negative sharply and the pitting corrosion susceptibility increased with the increase of Cl^- concentration; While above 600 mg/L, the pitting potentials shifted towardsnegative slowly and the stress corrosion cracking (SCC) susceptibility increased with the increase of Cl^- concentration.
关 键 词:304不锈钢 模拟循环冷却水 膜破裂电位 应力腐蚀破裂 临界Cl^-浓度
分 类 号:TG172.6[金属学及工艺—金属表面处理]