检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:孙旭光[1] 魏晴昀[2] 余明友[3] 朱忠尼[2]
机构地区:[1]空军雷达学院研究生管理大队,武汉430019 [2]空军雷达学院信息对抗系,武汉430019 [3]空军雷达学院科研部,武汉430019
出 处:《空军雷达学院学报》2008年第4期239-242,共4页Journal of Air Force Radar Academy
摘 要:针对大型多雷达阵地很容易遭受直接雷击、难以防护特点,分别利用传统避雷针及主动式防雷器,设计了三套防直击雷保护方案.通过对避雷针数量和安装高度的优化配置,较好地解决了多针防雷铁塔对雷达信号的影响.由分析、计算及仿真研究,得出利用主动式防雷器的方案为最佳方案.该方案解决了导弹、电子对抗、技侦等类似大型军事阵地的防雷问题.Aimed at the particularity that the large-scale multi-radar position is likely to be lightning struck, not easy to be protected, three schemes of lightning strike-proof were designed, making use of the traditional lightning rod and initiative lighting rod. The influence of multi-rod lightning-proof iron towers on radar signals was lowered much better in terms of optimizing configuration of the quantity and the setting height of lightning rod. By analysis, calculation and simulation, it proves that the project using initiative lightning rod is an optimum scheme, which solves the problem of lightning-proof for missile, electronic countermeasures, a technical reconnaissance and other large-scale military positions.