血清存放条件对血脂检测结果的影响  被引量:1

Influence of Serum Storage Condition to Lipid Test Results

在线阅读下载全文

作  者:唐孝成[1] 

机构地区:[1]成都市第二人民医院,四川成都610017

出  处:《现代临床医学》2008年第6期431-432,共2页Journal of Modern Clinical Medicine

摘  要:目的:观察新鲜血清标本在4℃~8℃贮存过程中6项血脂指标的稳定性。方法:按中生公司试剂盒说明,测定6项血脂指标在不同时间的稳定性。结果:血清甘油三酯(TG)和总胆固醇(TC)在28 d内的测定值无明显改变,但血清高密度脂蛋白胆固醇(HDL-C)、载脂蛋白A1(APOA1)与载脂蛋白B(APOB)测定值随存放时间的延长呈增高趋势,与室温3 h内结果比较,具显著性差异,至28 d具高度显著性差异。结论:测定TG和TC可适当延长存放时间,而HDL-C和APOA1、APOB在当日测定结果才稳定可靠。Objective :To oberve the stability of lipid, when the fresh serum specimens were storaged on 4 ℃ - 8 ℃. Methods:According to the exponent of BIOSINO BIO- TECHNOLOGY SCIENCE INC, measure 6 targets of the stability of lipid in the different time. Results: The serum - triglyceride (TG) and total cholesterol (TC) had no significant change in 28 d storage period, but serum high - density lipoprotein cholesterol ( HDL - C) , apolipoprotein A1 ( APOA1 ) and B(APOB) were increased, and compared with in 3 h at room temperature, the differences were significant, compared with 28 d, the differences were very obrious. Conclusion: HDL- C and APOA1, APOB should be measured as far as possible, and TG and TC may be appropriate to extend the storage time.

关 键 词:血清 血脂 稳定性 

分 类 号:R446.11[医药卫生—诊断学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象