折板转角对混凝沉淀效果影响的研究  被引量:3

Study on the effect of folded plate angle on flocculation

在线阅读下载全文

作  者:杨开明[1,2] 张建强[1] 杨小林[2] 王华[2] 

机构地区:[1]西南交通大学环境科学与工程学院,成都610031 [2]西华大学能源与环境学院,成都610039

出  处:《给水排水》2008年第11期27-29,共3页Water & Wastewater Engineering

基  金:四川省教育厅自然重点项目(05204097)

摘  要:通过絮凝动力学机理的分析,指出水流流态对混凝效果具有重要影响。设计了折板絮凝池试验模型,对不同角度的折板组合进行了研究。结果表明第1絮凝段采用90°异波折板,第2絮凝段采用90°同波波折板的组合对浊度的去除率最高,这对实际折板絮凝池的设计有很好的参考价值。By analyzing the mechanism of flocculation dynamics, it was demonstrated that flow pattern had a significant impact on flocculation effect. The model of folded plate flocculator was designed and the combinations of the folded plates with different angles were experimentally studied. The results showed that the combination of 90° opposite folded plates at the first flocculation section and 90° same wave folded plates at the second section is best of all the folded plates combinations for raw water turbidity removal, which is a useful reference to the design for actual folded plate flocculator.

关 键 词:折板絮凝池 机理 折板组合 浊度 

分 类 号:TU991.22[建筑科学—市政工程] TU991.23

 