三聚氰胺装置滞留液加热器堵塞原因分析  

To analyse the cause of residence liquid heater jamming in the melamine plant

在线阅读下载全文

作  者:李慧霞[1] 李娟[1] 

机构地区:[1]河南省中原大化集团有限责任公司三聚氰胺公司,河南濮阳457004

出  处:《化工中间体》2008年第12期57-59,共3页

摘  要:三聚氰胺装置超滤系统的滞留液加热器投入运行后频繁堵塞,经常造成高压废水处理工段断料,使系统大幅波动。经过研究、分析、试验,对换热器进行改造。在增加一个螺旋板式换热器后,发现其更适合滞留液的输送,运行十分稳定,没有再次发生堵塞的现象,基本解决了问题。The residence liquid heater of ultrafiltration system always jamming when it had been run into operation in the melamine plant, and cause the high-pressure wastewater treatment section break off, lead to the system disturbance. After investigation, analysis, a trial of change the heat exchanger mode, we found that the spiral heat exchanger is more suitable for the translation of residence liquid, it makes the operation more stable, the jamming didn't occurred any more. So, it can solve the problem completely.

关 键 词:滞留液加热器 堵塞 试验 

分 类 号:TQ226.62[化学工程—有机化工] TS112.1[轻工技术与工程—纺织材料与纺织品设计]

 