水和废水中总氮测定的关键问题研究  被引量:16

Studies on Key Issues in the Determination of Total Nitrogen in Water and Wastewater

在线阅读下载全文

作  者:张钧[1] 张庆军[1] 

机构地区:[1]泰州市环境监测中心站,江苏泰州225300

出  处:《污染防治技术》2008年第5期83-86,111,共5页Pollution Control Technology

摘  要:结合环境监测工作的实际,应用国标经典分析方法——《碱性过硫酸钾氧化-紫外分光光度法》(GB11894—1989),对水和废水中总氮的测定进行了系统的研究。概述了方法的原理,简介了方法的分析步骤,深入探讨了运用该方法进行水和废水中总氮测定的一些关键操作技术问题,指出在标准分析方法的基础上,选用纯度较高的过硫酸钾,提高氧化消解温度至126—127℃,延长过硫酸钾的氧化消解时间至50min,消解后自然冷却2—3h,能确保水样总氮分析的精密度和准确度。Combined with the work practice of environmental monitoring, the application of the national standard classical analytical method - Alkaline potassium persulfate digestion -UV spectrophotometric method(GBl1894--1989) to the determination of total nitrogen in water and waste water was studied systematicly. The principle of the method was summed up, the analysis steps of the method was briefly introduced, some key operating technology problems in the determination of ammonia nitrogen in water and waste water by using this method have been analyzed in depth,it was pointed out that on the base of standard method,through chosing the high- purity potassium persulfate, improving the temperature of oxidation and digestion to 126 -127 centigrade,prolonging the time of oxidation and digestion for potassium persulfate to 50 minutes and cooling 2 -3 hours after heating,the aecuracy and precision in the analysis of total nitrogen of water samples can be guaranteed.

关 键 词:总氮 紫外分光光度法 水和废水 关键问题 

分 类 号:X830.5[环境科学与工程—环境工程] X832

 