嵌入式涡街流量计的设计与算法研究  被引量:1

Design and Algorithm Study of Embedded Vortex Flow Meter

在线阅读下载全文

作  者:李银华[1] 王燕[1] 闫艳梅[1] 

机构地区:[1]郑州轻工业学院模糊控制技术中心,河南郑州450002

出  处:《仪表技术与传感器》2008年第11期42-44,共3页Instrument Technique and Sensor

摘  要:传统涡街流量计由于抗干扰性差、测量精度低等难以满足实际测量的需求,研究和开发高抗扰型涡街流量计已成为当前流量测量领域的重要发展方向。针对现有产品存在的问题,设计了一种嵌入式涡街流量计,给出了硬件组成结构和相关电路原理图;并在信号处理算法上,采用Chirp-Z变换的频谱校正方法,对经FFT变换后的涡街信号的频谱主瓣进行局部细化,从而在运算量增加不多的情况下,提高了涡街流量计的测量精度。并通过Matlab仿真实验对该频谱校正方法进行有效性验证。仿真结果表明:该方法具有校正精度高,响应速度快和使用灵活的特点。It is difficult to satisfy practical measurement because of poor noise immunity and low precision of traditional vortex flow meter. Therefore, it is prevailing study tendency in the flux measurement to research and exploit vortex flow meter with high noise immunity. Aiming at the existing problems of the present vortex flow meter, a new embedded vortex flow meter was de- signed, the hardware configuration and related circuits were given; on the aspects of algorithm of signal processing, the spectrum correction method of the chirp-Z transform was presented to improve the measurement precision through reducing the frequency space of the main lobe region of the spectrum based on FFT without increasing more operations. Meanwhile, in order to verify its validity, the Matlab simulations were carried out. The simulation results show that the method has the advantages of high accuracy, rapid speed and flexibility.

关 键 词:涡街流量计 信号处理 CHIRP-Z变换 FFT 变换 

分 类 号:TP274[自动化与计算机技术—检测技术与自动化装置]

 