作 者:陶绪泉[1] 王怀生[2] 崔艳云[2] 崔慧[2] 李斌[2]
机构地区:[1]聊城大学材料科学与工程学院,山东聊城252059 [2]聊城大学化学化工学院,山东聊城252059
出 处:《塑料》2008年第6期91-93,共3页Plastics
摘 要:采用微波消解制样技术,用电感耦合等离子体发射光谱(ICP-AES)法测定聚氯乙烯(PVC)塑钢门窗中的Pb、Zn、Ti、Cu等重金属元素含量,确定了实验的最佳测定条件。结果表明:方法的检出限为0.01840~1.034μg/mL,回收率为94.23%~103.5%,相对标准偏差在4.6%以内。该方法灵敏度高、准确、快速,可满足PVC塑钢门窗中金属元素的常规测定。Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) method was used to determine heary metal elements such as Pb,Zn,Ti and Cu in PVC plastic-steel door and window based on microwave digestion samplemaking technique. The optimum determination condition was obtained. The results showed that the sensitivity of the detection limit was 0. 01840 - 1. 034 μg/mL,the RSD was less than 4. 6 % and the recovery was from 94.23 % to 103.5 %. This method was accurate,quick and could meet the coventional determining of metal elements in PVC plastic-steel door and window.
关 键 词:微波消解 聚氯乙烯 塑钢门窗 重金属元素 电感耦合等离子体发射光谱
分 类 号:TQ325.3[化学工程—合成树脂塑料工业]