摘  要:在实验室内,利用液压伺服疲劳试验机,对水泥混凝土试件,采取三分点加载法,研究在常温、冻融循环后和-40℃冰冻状态下,两种纤维掺入量(0.9 kg/m31、.8 kg/m3)的聚丙烯纤维网混凝土和0掺入量的基准混凝土疲劳性能。试验表明纤维掺入量为0.9 kg/m3的混凝土性价比较高。Using three-point method and hydraulic servo fatigue test machine, this paper does a test on fatigue performance of concrete with different amount of reticular polypropylene fibre (0.9 km/m^2 , 1.8 km/ m^2) under normal temperature, freeze-thaw cycle and forty degrees of frost respectively in lab. The Weibull distribution is used to analyze the fatigue performance of concrete. The test results show that the fatigue performance of concrete with 0.9 k/m^2 reticular polypropylene fibre is better.