水质监测中总磷无损的近红外光谱分析研究  被引量:17

Investigation on the Non-Chemical Method for Monitoring Total Phosphate in Water

在线阅读下载全文

作  者:刘宏欣[1,2] 张军[3] 王伯光[4] 刘慧璇[4] 卢锷[1] 

机构地区:[1]中国科学院长春光学精密机械与物理研究所,长春130033 [2]中国科学院研究生院,北京100039 [3]暨南大学理工学院光电工程系,广州510632 [4]暨南大学理工学院环境工程系,广州510632

出  处:《分析科学学报》2008年第6期664-666,共3页Journal of Analytical Science

摘  要:本文对天然水样的近红外光谱与水样总磷(TP)含量进行了相关性研究,并建立了水质总磷的近红外光谱(NIRS)分析方法。结果表明:NIRS方法建立的定量分析模型所得TP含量与国标法得到结果的相关性达到0.908,并且在显著性水平大于0.05的条件下对NIRS方法与国标法的测定结果进行t检验,二者无显著性差异,说明了NIRS方法定量分析地表水中低含量总磷的可行性。The aim of this paper is to study the non-chemical method for monitoring total phosphate (TP). Near infrared spectroscopy (NIRS) and stepwise multiple linear regression (SMLR) have been used to build the models of TP. The NIRS method and the national standard method (NSM) have been compared with each other. The experimental results demonstrate that there is no significant difference between NIRS method and NSM under the condition of the significance level greater than 0.05. Whatever, the merit of NIRS method is that no chemical is needed and secondary pollution is avoided. The results of this paper provide a foundation for the application and further development of the online automatic monitoring instruments on TP.

关 键 词:总磷 无损检测 近红外光谱 

分 类 号:O657.33[理学—分析化学]

 