检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
出 处:《Chinese Journal of Chemical Engineering》2008年第6期849-855,共7页中国化学工程学报(英文版)
基 金:Supported by the National High Technology Research and Development Program of China(2007BAF13B01)
摘 要:The single-phase pressure drop and heat transfer in a rotor-assembled strand inserted tube were measured using water as the working fluid.Experiment using a smooth tube was carried out to calibrate the experimental system and the data reduction method.In the experiment,fixed mounts were used to eliminate the entrance effect. The experimental results of smooth tube show that employment of fixed mounts leads to a visible bias of friction factor at relative low Reynolds numbers,although it does not significantly affect the Nusselt numbers.The measured data of inserted tube reveal that rotor-assembled strand can significantly improve heat transfer with the Nusselt number increased by 101.6%-106.6%and the overall heat transfer coefficient increased by 58.1%-67.4%within the Reynolds number range of 20000 to 36000.Meanwhile,friction factor increases by 52.2%-84.2%within the same Reynolds number range.The correlations of Nusselt number and friction factor as function of the Reynolds number and Prandtl number were determined through multivariant linear normal regression.The single-phase pressure drop and heat transfer in a rotor-assembled strand inserted tube were measured using water as the working fluid. Experiment using a smooth tube was carried out to calibrate the experimental system and the data reduction method. In the experiment, fixed mounts were used to eliminate the entrance effect. The experimental results of smooth tube show that employment of fixed mounts leads to a visible bias of friction factor at relative low Reynolds numbers, although it does not significantly affect the Nusselt numbers. The measured data of inserted tube reveal that rotor-assembled strand can significantly improve heat transfer with the Nusselt number increased by 101.6%-106.6% and the overall heat transfer coefficient increased by 58.1%-67.4% within the Reynolds number range of 20000 to 36000. Meanwhile, friction factor increases by 52.2%-84.2% within the same Reynolds number range. The correlations of Nusselt number and friction factor as function of the Reynolds number and Prandtl number were determined through multivariant linear normal regression.
关 键 词:heat transfer enhancement rotor-assembled strand friction factor DEPENDENCY
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.15