xperimental Study of Heat Transfer Enhancement and Friction Loss Induced by Inserted Rotor-assembled Strand (I) Water  被引量:4

xperimental Study of Heat Transfer Enhancement and Friction Loss Induced by Inserted Rotor-assembled Strand (I) Water

在线阅读下载全文

作  者:谢鹏程 李锋祥 丁玉梅 阎华 关昌峰 杨卫民 

机构地区:[1]College of Mechanical and Electrical Engineering, Beijing University of Chemical Technology, Beijing 100029, China

出  处:《Chinese Journal of Chemical Engineering》2008年第6期849-855,共7页中国化学工程学报(英文版)

基  金:Supported by the National High Technology Research and Development Program of China(2007BAF13B01)

摘  要:The single-phase pressure drop and heat transfer in a rotor-assembled strand inserted tube were measured using water as the working fluid.Experiment using a smooth tube was carried out to calibrate the experimental system and the data reduction method.In the experiment,fixed mounts were used to eliminate the entrance effect. The experimental results of smooth tube show that employment of fixed mounts leads to a visible bias of friction factor at relative low Reynolds numbers,although it does not significantly affect the Nusselt numbers.The measured data of inserted tube reveal that rotor-assembled strand can significantly improve heat transfer with the Nusselt number increased by 101.6%-106.6%and the overall heat transfer coefficient increased by 58.1%-67.4%within the Reynolds number range of 20000 to 36000.Meanwhile,friction factor increases by 52.2%-84.2%within the same Reynolds number range.The correlations of Nusselt number and friction factor as function of the Reynolds number and Prandtl number were determined through multivariant linear normal regression.The single-phase pressure drop and heat transfer in a rotor-assembled strand inserted tube were measured using water as the working fluid. Experiment using a smooth tube was carried out to calibrate the experimental system and the data reduction method. In the experiment, fixed mounts were used to eliminate the entrance effect. The experimental results of smooth tube show that employment of fixed mounts leads to a visible bias of friction factor at relative low Reynolds numbers, although it does not significantly affect the Nusselt numbers. The measured data of inserted tube reveal that rotor-assembled strand can significantly improve heat transfer with the Nusselt number increased by 101.6%-106.6% and the overall heat transfer coefficient increased by 58.1%-67.4% within the Reynolds number range of 20000 to 36000. Meanwhile, friction factor increases by 52.2%-84.2% within the same Reynolds number range. The correlations of Nusselt number and friction factor as function of the Reynolds number and Prandtl number were determined through multivariant linear normal regression.

关 键 词:heat transfer enhancement rotor-assembled strand friction factor DEPENDENCY 

分 类 号:TQ02[化学工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象