Preliminary Study on Diagnostic Techniques for Transient Plasma Generated by Hypervelocity Impact  被引量:16

Preliminary Study on Diagnostic Techniques for Transient Plasma Generated by Hypervelocity Impact

在线阅读下载全文

作  者:唐恩凌 张庆明 何远航 张健 

机构地区:[1]School of Equipment Engineering,Shenyang Ligong University,Shenyang 110168,China State Key Laboratory of Explosion Science and Technology,Beijing Institute of Technology,Beijing 100081,China [2]State Key Laboratory of Explosion Science and Technology,Beijing Institute of Technology,Beijing 100081,China [3]School of Equipment Engineering,Shenyang Ligong University,Shenyang 110168,China

出  处:《Plasma Science and Technology》2008年第6期735-738,共4页等离子体科学和技术(英文版)

基  金:National Natural Science Foundation of China(No.10772028)

摘  要:A fast-sweep Langmuir probe (FSLP) diagnostic system was designed and applied to obtain the electron temperature fluctuations of a transient plasma. The diagnostic system consists of a single Langmuir probe driven by a high frequency sinusoidal voltage. The current-voltage I- V characteristics can be recorded by sweeping the voltage and measuring the current with an appropriate circuit. This new instrument is based on a dual channel circuit that compensates for stray capacitance. The current and voltage spectra were acquired from the probe synchronously by a digital oscilloscope. The aim of this work was to apply the FSLP diagnostic system to a time- dependent plasma generated by a hypervelocity impact between the LY12 Aluminum projectile and LY12 Aluminum target.A fast-sweep Langmuir probe (FSLP) diagnostic system was designed and applied to obtain the electron temperature fluctuations of a transient plasma. The diagnostic system consists of a single Langmuir probe driven by a high frequency sinusoidal voltage. The current-voltage I- V characteristics can be recorded by sweeping the voltage and measuring the current with an appropriate circuit. This new instrument is based on a dual channel circuit that compensates for stray capacitance. The current and voltage spectra were acquired from the probe synchronously by a digital oscilloscope. The aim of this work was to apply the FSLP diagnostic system to a time- dependent plasma generated by a hypervelocity impact between the LY12 Aluminum projectile and LY12 Aluminum target.

关 键 词:hypervelocity impact fast-sweep Langmuir probe electron temperature 

分 类 号:O531[理学—等离子体物理]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象