检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]上海电力学院电力与自动化工程学院,上海200090
出 处:《上海电力学院学报》2008年第4期377-380,共4页Journal of Shanghai University of Electric Power
摘 要:分析了电缆隧道火灾的起因、危险性及特点,比较分析了电缆隧道的灭火技术,提出了一套高压细水雾灭火系统解决方案,并结合某钢厂电缆隧道项目对高压细水雾系统工程进行设计,研究成果和实践对计算机房、控制室、油浸变压器、档案库房、高压配电室等重要危险场所细水雾灭火系统的设计具有参考价值.The causes of the cable tunnel fire, the fire risk, and the characteristics of the fire are analyzed. The different extinguishing technologies in cable tunnel are compared. A perfect high pressure water mist system solution is presented, which is designed for a specific cable tunnel project in a steel plant. The research result has an important reference value for the fire extinguishing system designing of other dangerous places, such as computer rooms, control rooms, oil-immersed transformers, archives and high voltage distribution rooms.
分 类 号:U458.1[建筑科学—桥梁与隧道工程] TU998.1[交通运输工程—道路与铁道工程]