检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李武帅[1] 彭春霖[1] 袁甫[1] 綦文娣[1] 匡洲献 徐承浩
机构地区:[1]中科院长春应用化学研究所国家电化学和光谱研究分析中心
出 处:《分析测试学报》1998年第1期18-21,共4页Journal of Instrumental Analysis
摘 要:用2-乙基己基膦酸单2-乙基己酯萃取色谱分离-原子发射光谱测定超高纯Sm2O3、Eu2O3、Gd2O3中痕量稀土杂质,可用于纯度为999999%~9999999%(不含非稀土杂质)Sm2O3、Eu2O3、Gd2O3的纯度分析,14个稀土杂质的回收率在67%~133%之间,相对标准偏差±64%~±184%,分离周期10~14h。A chemical separation_atomic emission spectrometric method was established for the determination of 14 rare earth impurities in Sm 2O 3,Eu 2O 3 and Gd 2O 3 of ultra_high purity(99 9999%~ 99 99999 %).Extraction chromatography with mono_2_ethylhexyl_2_ethylhexyl phosphonate (commercial name:P507) as the stationary phase was employed for the separation of rare earth impurities. All the rare earth impurities were eluted with HCl+NH 4Cl solution and 4 mol·L -1 HCl solution. The impurities were then determined by atomic emission spectrometry .The recoveries are 67%~133%, while the relative standard deviations are 6 4%~18 4%.The separation period is 10~14 h.