两级生物膜处理合成洗涤剂废水  被引量:3

Study on the treatment of synthetic detergent wastewater by anaerobic biofilter and aerobic biological contact oxidation process

在线阅读下载全文

作  者:李健[1,2] 于洪江[1] 李谦定[1] 

机构地区:[1]西安石油大学,陕西西安710065 [2]延安炼油厂,陕西延安727406

出  处:《工业水处理》2008年第12期93-95,共3页Industrial Water Treatment

摘  要:采用厌氧生物滤池(AF)—好氧生物接触氧化(BCO)联合工艺对合成洗涤剂(LAS)废水进行处理试验。结果表明,AF反应器在HRT=24h、温度(32±2)℃、pH为7~8、营养母液质量浓度5mg/L条件下,BCO反应器在HRT=12h、常温、DO为4~5mg/L条件下,对LAS和COD的去除率分别可达到85%和95%,出水达到国家《污水综合排放标准》(GB8978—1996)规定的一级排放标准。The anaerobic biofilter(AF) and aerobic biological contact oxidation (BCO) process have been used for treating synthetic detergent (LAS) wastewater. The results show that in the AF reactor the conditions are: HRT= 24 h, temperature is (32±2)℃, pH is 7-8 and nutrient solution mass concentration is 5 mg/L, and in the BCO reactor the conditions are: HRT=12 h, DO is 4-5 mg/L and at room temperature, the removal rates of LAS and COD are 85% and 95%, respectively. The indexes of the effluent can reach the standard of GB 8978--1996.

关 键 词:厌氧生物滤池 好氧生物接触氧化 生物膜 合成洗涤剂废水 

分 类 号:TQ085[化学工程]

 